6.5 Edge 2 Release Notes
15 February 2021
We are happy to introduce Virtuozzo OnApp 6.5 Edge 2 (6.5.edge2-16). This document lists features, improvements, and fixes implemented for all available Virtuozzo OnApp components within the 6.5 Edge 2.
Before You Upgrade
- Virtuozzo OnApp 6.5 Edge 2 is an edge release that is not designed to be installed on production environments.
- You can update to Virtuozzo OnApp 6.5 Edge 2 from Virtuozzo OnApp 6.4 and Virtuozzo OnApp 6.5 Edge 1.
The following table lists all the features, improvements, and fixes included in Virtuozzo OnApp 6.5 Edge 2 for all available components.
Features & Improvements
| Type | Key | Release Notes |
|---|---|---|
| Virtuozzo OnApp | ||
| WIZ-69 | If you have backup resources using a backup plugin attached to your virtual server, now when the virtual server owner is changed, the backup resources can be removed. | |
| TA-179 | The VS data store that doesn’t have a free disk or its free space is less than the smallest disk size is now excluded from full, hot full, and xen2kvm migrations. | |
| TA-194 | Updated the pinned certificates for api.yubico.com. | |
| REFLEX-74 | Updated the info box at the Service Catalog page. | |
| Installer | ||
| INSTALLER-550 | Build RPM packages for CentOS 7.x and 8.x to provide Ruby 2.6.6 and Virtuozzo OnApp required Gems. | |
| CloudBoot | ||
![]() | CLOUDBOOT-651 | A CentOS7 KVM ramdisk's network interfaces were named according to udev rules. |
| CLOUDBOOT-657 | Updated onapp-ramdisk-tools with:
| |
| CLOUDBOOT-712 | Now the memory of the integrated storage controller is checked with /usr/pythoncontroller/check_ram_before_upgrade.py script before each onapp-ramdisk package is upgraded to prevent the IS discs from malfunctioning. | |
CLOUDBOOT-714 | Updated all ramdisks with onappstore-6.5-8338-master.x86_64.rpm . | |
| CLOUDBOOT-715 | Updated the following components for CentOS7 KVM ramdisk:
| |
| Integrated Storage | ||
STORAGE-946 | Added new command, onappstore nodecpuinfo, into the CLI command-line interface, which gets storage node VS CPU and memory usage. | |
| SUPPORT-3376 | Made it possible to save persistent logs to one of the node drives on the current Storage Controller. | |
Fixes
Type | Key | Release Notes | Affected Versions |
|---|---|---|---|
| CORE-17807 | An incorrect hint appeared at the Add New Compute Zone page while trying to create a new compute zone. | 6.4 |
| REFLEX-38 | Unlock any user permission was missed in the CP so that the Unlock account button did not show. | 6.3 |
| TA-155 | Few buttons did not show correctly at the Add New CDN Resource Page. | 6.2 - 6.4 |
| TA-156 | It was impossible to add a node to the Load Balancer cluster type via API. | 6.3 |
| TA-157 | There was an error at the breadcrumb when you visited the Billing Statistics page of a CDN resource. | 6.2 |
| TA-158 | It is impossible to edit nodes to load balancing ports via API. | 6.3 |
| TA-159 | If you removed the initial node which was created during the process of load balancer creation, it was impossible to add any new node to the load balancer. | 6.1 |
| TA-160 | The High Availability page was not shown correctly during the processing of the InitializeHA transaction. | 6.3 |
| TA-161 | It was possible to pick the Full migration option for OVA/ISO VS even though this option is not available. | 6.2 |
| TA-162 | The password was not set when you tried to save the credentials to a CDN resource while editing it or creating a new one via Advanced Settings. | 6.3 - 6.4 |
| TA-163 | When you had submitted more than 1000 URLs for the Purge or Prefetch pages, you saw a notification that the request was successfully scheduled, although Aflexi API returned the 422 Unprocessable Entity Error . | 6.2 |
| TA-182 | The price for VSs network interfaces did not according to a new zone price after FullMigrate and HotFullMigrate transactions. | 6.3 Edge 1 |
| WIZ-655 | The SolidFire volume from which the backup has been copied was not removed once the copying was completed. | 6.2 - 6.2 Patch 1 |
| VMWARE-181 | It was impossible to import Windows virtual server created on the vCenter with a hostname longer than 15 symbols into Virtuozzo OnApp CP. | 6.3 - 6.4 Edge 1 |
| VMWARE-199 | When you tried to deploy a new resource pool from the orchestration model, the last transaction CreateOrgVDCNetwork failed. | 6.3 - 6.4 |
| VMWARE-230 | The vCloud default_timeout value in on_app.yml was not applied during the MigrateToDataStore transaction. | 6.3 - 6.4 |
| STORAGE-2273 | A fully loaded Storage Controller was allowing to overcommit memory which could cause OOM issues. | 6.1 Patch 1 - 6.3 |
| STORAGE-2313 | It was impossible to get the SMART information from HDD after the software update. | 6.3 Edge 2 - 6.3 |
| STORAGE-2323 | If you did not have enough memory for the storage upgrade, after the upgrade to the Virtuozzo OnApp 6.3, you might face difficulties with the integrated storage discs repairs. | 6.3 Edge 2 - 6.3 |