6.6 Edge 2 Release Notes
14 July 2021
Before You Upgrade
- Virtuozzo OnApp 6.6 Edge 2 (6.6.edge2-25) is an edge release that is not designed to be installed on production environments.
- You can update to Virtuozzo OnApp 6.6 Edge 2 from Virtuozzo OnApp 6.5 or 6.6 Edge 1.
The following table lists all the features, improvements, and fixes included in Virtuozzo OnApp 6.6 Edge 2 for all available components.
Features & Improvements
| Type | Key | Release Notes |
|---|---|---|
| Virtuozzo OnApp | ||
WIZ-517 (SUPPORT-3073) | Now we store disk partition UUIDs during backup procedure and restore disk partition UUIDs during backup restore procedure to solve the issues when the UUIDs are changed and VS refuses to boot. | |
| WIZ-752 (SUPPORT-3216) | Made UUID constant for virtual servers so now it does not change after VS reboots, shutdowns, etc. | |
| TA-60 (SUPPORT-2808) | Now you can define the primary IP for the interface to be used as source IP for outgoing traffic by default. | |
| TA-93 | Now you can edit the label of an SDN network at the Edit SDN Network page. | |
TA-114 | Improved validation to Host field at the Edit SDN Manager page. | |
| TA-303 (SUPPORT-3469) | Started to support the OpenDaylight Controller 0.14.0 version. | |
| UIUX-118 | Updated UI at the Backups page. | |
| UIUX-119 | Updated UI at the Backup Resources page. | |
UIUX-120 | Updated UI at the Recovery Points page. | |
| UIUX-121 | Updated UI at the Service Add-Ons page. | |
| UIUX-123 | Updated UI at the Custom Recipe Variables page. | |
UIUX-128 | Updated UI at the Adjust Resource Allocations page. | |
UIUX-130 | Updated UI at the Snapshots for this Virtual Server page. | |
| vCenter and vCloud | ||
VMWARE-166 | Now you can see the sub-allocated IPs for NSX-T edge gateways at the Edge Gateway Overview page. | |
VMWARE-426 | Reduced execution time of ConfigureOperatingSystem transaction. | |
| VMWARE-530 | Started to support VMware Cloud Director version 10.2.2. | |
VMWARE-543 (SUPPORT-3477) | Started to support Windows 10 virtual servers in VMware environment. | |
VMWARE-545 | Now you can access NSX-V edge gateway rate limits via API request. | |
| Installer | ||
INSTALLER-568 | Built RPM packages for CentOS 7.x and 8.x to provide Ruby new version 2.7.3 and Virtuozzo OnApp required Gems. | |
Fixes
Type | Key | Release Notes | Affected Versions |
|---|---|---|---|
| TA-34 | It was impossible to add second SDN node to SDN manager. | 6.4 0 - 6.6 Edge 1 |
| VMWARE-222 (SUPPORT-3422) | The L1 stats collection for the vCenter failed with the error divided by 0 when trying to add empty cluster from vCenter to the Control Panel. | 6.4 - 6.6 Edge 1 |
| VMWARE-248 | When you were creating a new compute zone, the VPC option was available in the Server type drop-down list when the license did not include it. | 6.0 Patch 12 - 6.6 Edge 1 |
| VMWARE-562 | An Ubuntu 18.04 LTS image failed during the deployment on the environment. | 6.5 |
| WIZ-848 | You could see 500 Internal Server Error when applying more then 200 firewall rules for a virtual server. | 6.4 - 6.6 Edge 1 |
| WIZ-853 | The Baremetal Sever Details page did not work as expected. | 6.5 - 6.6 Edge 1 |
| STORAGE-2474 (SUPPORT-3390) | When a VS was fully-migrated between zones, the new disks were created without regards to local read policy on the destination zone. | 6.2 - 6.6 Edge 1 |
| CORE-18017 (SUPPORT-3468) | After you run `cd /onapp/interface/ && rake -T` cmd in console, there could appear warning. | 6.4 - 6.6 Edge 1 |